The Fronius Primo GEN24 208-240 inverter has detected an internal fault associated with its integrated DC disconnector. This indicates a potential malfunction of the disconnector or its internal sensing, preventing safe and reliable operation.
Click steps to track your progress.
Manually operate the external DC disconnector several times to ensure it moves freely and makes proper contact in both ON and OFF positions.
Check the DC input wiring to the Fronius Primo GEN24 208-240 inverter, ensuring all connections are secure and there are no signs of damage or corrosion that could affect the disconnector's operation or sensing.
Perform a full power cycle of the inverter, including opening the AC breaker, operating the DC disconnector, waiting, and then re-energizing.
If the disconnector appears physically fine but the error persists, there may be an issue with the internal sensing mechanism of the disconnector.
If the fault does not clear, the DC disconnector or its internal control may be faulty, requiring service; contact Fronius service.