Fronius · Primo GEN24
The Fronius Primo GEN24 208-240 inverter has detected an internal fault related to its surge protection device (SPD). This indicates that the SPD may have failed, potentially due to a voltage surge, compromising the inverter's protection against transient overvoltages.
Click steps to track your progress.
Inspect the surge protection device (SPD) within the Fronius Primo GEN24 208-240 inverter's connection area (if visible and accessible by qualified personnel) for any fault indicators or tripped modules.
Perform a full power cycle of the inverter by cycling both AC and DC disconnects, waiting, and then reapplying power.
Check for any signs of recent electrical surges or lightning strikes in the vicinity that could have caused the SPD to activate or fail.
If the SPD has modular cartridges, verify they are correctly seated or check for indicators that they require replacement.
If the fault persists and the SPD appears damaged or faulty, contact Fronius service for inspection and potential replacement of the SPD.