801

AFCI (Arc Fault Circuit Interrupter) event

Fronius · Primo GEN24

What does 801 mean?

The Fronius Primo GEN24 208-240 inverter's Arc Fault Circuit Interrupter (AFCI) has detected a dangerous electrical arc in the PV array. This is a critical safety feature that shuts down the inverter to prevent fire hazards.

Common Causes

  • AFCI event (arc fault).
  • Loose connections in PV array.
  • Damaged cables or connectors in PV array.
  • Faulty PV module junction box.
  • Rodent damage to PV cables.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Immediately disconnect the PV arrays using the DC disconnector and the AC breaker, then perform a thorough visual inspection of the entire PV array wiring.

  2. 2

    Systematically check all PV module connectors (MC4), string combiner box terminals, and DC cable connections for tightness, signs of arcing, melting, or corrosion.

  3. 3

    Inspect all DC cables for physical damage, insulation breakdown, rodent damage, or pinched sections.

  4. 4

    Examine the junction boxes on the back of each PV module for signs of internal arcing or moisture ingress.

  5. 5

    If the fault location cannot be identified visually, use specialized arc fault detection equipment or systematically isolate strings/modules for testing. Contact qualified PV service personnel.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026