901

Backup power operation not possible

Fronius · Primo GEN24

What does 901 mean?

The Fronius Primo GEN24 208-240 inverter is unable to switch to or maintain backup power operation (PV Point or Essential Backup). This means the system cannot provide emergency power to critical loads during a grid outage.

Common Causes

  • Backup power operation not possible.
  • Battery not connected.
  • Battery not charged.
  • Grid still present (backup power not required).
  • Incorrect wiring of backup power connection.
  • Faulty transfer switch (external or internal).

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that a compatible battery system is correctly connected to the Fronius Primo GEN24 208-240 inverter and is sufficiently charged for backup operation.

  2. 2

    Check the status of the public grid; backup power will only activate during a grid outage.

  3. 3

    Inspect the wiring and connections for the backup power circuit (e.g., PV Point, Essential Backup box) to ensure they are correctly installed as per the manual.

  4. 4

    If an external transfer switch or contactor is used, verify its operational status and control signals.

  5. 5

    Ensure all necessary backup power features are enabled in the inverter's settings (e.g., "PV Point active" or "Essential Backup mode").

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026