SEW Eurodrive · MOVIDRIVE system
Communication between the inverter and the safety option has been interrupted, potentially due to a loose connection or a subcomponent fault within the safety option. This prevents proper safety function and inhibits the output stage, compromising system safety.
Click steps to track your progress.
Remove and carefully re-insert the safety option card, confirming a firm and secure connection.
Inspect the edge connector of the safety option card and the corresponding slot on the inverter for bent pins or debris.
Check for proper grounding and shielding of the inverter cabinet to mitigate potential external EMI.
Monitor internal diagnostic logs of the inverter for other related communication bus errors.
Measure internal power supply voltages (e.g., 5VDC, 3.3VDC) at test points on the inverter's mainboard to ensure stability.