SEW Eurodrive · MOVIDRIVE system
The encoder evaluation system is signaling a critical system error for Encoder 1, possibly due to a multi-turn encoder being outside its configured track area, incorrect limits, or faulty numerator/denominator factors. This indicates a severe issue with position calculation or encoder setup, risking incorrect positioning and drive instability.
Click steps to track your progress.
Verify the configured multi-turn limits (e.g., P7-07, P7-08) against the encoder's specified multi-turn range.
Inspect the encoder's battery (if multi-turn) for proper connection and measure its voltage (e.g., 3.6VDC).
Confirm the numerator (P7-05) and denominator (P7-06) scaling parameters match the encoder's resolution and application requirements.
Check the encoder's internal diagnostic register (if accessible via communication, e.g., using SDO access) for specific error codes.
Attempt to re-initialize the encoder's multi-turn counter (refer to drive/encoder manual for specific procedure).