SEW Eurodrive · MOVIDRIVE system
Encoder 1's data signal line is permanently stuck at a low level, indicating a critical communication issue. This suggests a wiring problem (e.g., short to ground) or a defective encoder, preventing reliable position feedback and risking uncontrolled drive behavior.
Click steps to track your progress.
Disconnect encoder cable from drive and encoder. Use a multimeter to check for continuity between the affected data line (e.g., A signal) and the 0V conductor within the encoder cable.
Verify the encoder's supply voltage (e.g., 5VDC or 24VDC) at the encoder connector using a multimeter while powered, ensuring it's stable.
Inspect the encoder cable for physical damage, pinching, or crushing that could cause internal shorts.
If available, swap the encoder with a known good one to determine if the fault is internal to the encoder unit.
Check drive parameters related to encoder type and signal levels (e.g., Parameter P6-01, P6-02) to ensure they match the connected encoder specifications.