SEW Eurodrive · MOVIDRIVE system
The data signal from Encoder 1 is persistently at a low level. This typically points to a wiring issue or a defect within the encoder unit, resulting in lost or incorrect position feedback and impacting precise drive control.
Click steps to track your progress.
Power down the drive, disconnect Encoder 1 cable from terminal X1, and measure resistance between DATA+ and 0V.
Verify continuity of the Encoder 1 data lines (DATA+ and DATA-) and their respective return paths from encoder connector to drive terminal X1 using a multimeter.
Measure the supply voltage for Encoder 1 at the encoder's power input terminals (e.g., +10V or +24V to 0V).
Using an oscilloscope, monitor the data line signal (DATA+ and DATA- differential) at terminal X1 while slowly rotating the motor shaft.
Exchange Encoder 1 with a known-good encoder of the same type and test system operation.