An error bit has been set in the SSI protocol by Encoder 1, indicating a data or communication problem. This can result from incorrect startup parameters, encoder settings, wiring issues, or external interference, affecting position feedback reliability.
Click steps to track your progress.
Cross-reference drive parameters P3-55 (SSI resolution) and P3-56 (SSI number of turns) against the Encoder 1 datasheet and adjust if necessary.
Visually inspect the routing of the Encoder 1 cable to ensure it is separated from high-current power cables and that shielding is continuous.
Capture SSI clock and data signals at drive terminal X1 using an oscilloscope to identify any transient noise or signal distortions.
Perform a resistance check on all SSI signal lines (CLOCK+, CLOCK-, DATA+, DATA-) and ground connection from drive terminal X1 to encoder connector.
Reset the Encoder 1 configuration parameters in the drive (e.g., P3-50 to default) and reconfigure carefully.