SEW Eurodrive · MOVIDRIVE system
An error occurred while monitoring the signal level from Encoder 1, where the signal vector exceeded its permitted limit. This could indicate an issue with the encoder's physical mounting position affecting its signal output or data integrity.
Click steps to track your progress.
Inspect Encoder 1's mechanical mounting for tightness, alignment, and absence of excessive vibration.
Monitor Encoder 1's raw signal output (e.g., sine/cosine) on an oscilloscope to detect vector anomalies.
Check all Encoder 1 cable connections (e.g., X11) for secure termination and verify shield integrity.
Review the drive's encoder monitoring parameters (e.g., P6-10) to ensure appropriate limits are set for the application.
If using a resolver, check the resistance values of the primary and secondary windings against the manufacturer's specifications.