An error was detected during the quadrant check for the sine encoder (Encoder 1), indicating a problem with signal integrity or phase relationship. This can be caused by wiring issues, EMC interference, or a defective encoder, leading to incorrect position feedback.
Click steps to track your progress.
Verify the wiring of Encoder 1's sine/cosine signals (e.g., terminals A+, A-, B+, B-) to ensure correct phase relationship.
Connect an oscilloscope to Encoder 1's sine and cosine signals (e.g., A+ and B+ referenced to A-) at the drive input (e.g., X11) and check for correct 90-degree phase shift and equal amplitudes.
Ensure Encoder 1 cable shielding is properly terminated to protective earth at both the encoder and the drive.
Check Encoder 1's supply voltage (e.g., 5VDC or 24VDC) at the encoder to ensure stable power delivery.
Review the drive's encoder configuration parameters (e.g., P6-01 Encoder type) to confirm it is set for a sine/cosine encoder.