SEW Eurodrive · MOVIDRIVE system
Encoder 2 is reporting an internal fault status, indicating a malfunction within the encoder hardware or software. This compromises the accuracy and reliability of position feedback, potentially causing drive control issues.
Click steps to track your progress.
Measure the supply voltage to Encoder 2 at its input terminals (e.g., +10V to 0V or +24V to 0V) for stability and correct level.
Cycle power to the drive and Encoder 2, then observe if the internal fault clears upon restart.
Check for any documented firmware updates for Encoder 2 that address known internal fault conditions.
Monitor the ambient temperature around Encoder 2 to ensure it is operating within its specified temperature range.
If accessible, perform an internal diagnostic check on Encoder 2 using manufacturer-specific software or tools.