SEW Eurodrive · MOVIDRIVE system
The drive's position for Encoder 2 has exceeded the maximum allowable travel range defined by the current position mode (8382.10). This indicates a configuration error or unexpected machine movement, which can lead to mechanical limits being hit or incorrect positioning.
Click steps to track your progress.
Verify and adjust the maximum travel range parameter (P2-15) to accommodate the full mechanical stroke of the axis.
Check the mechanical limits and end stops of the machine axis to ensure they are physically intact and functioning.
Re-perform the homing procedure for Encoder 2, ensuring the machine reaches the correct reference position.
Verify the encoder scaling factors and resolution parameters (e.g., P2-16, P3-55, P3-56) match the machine mechanics and encoder type.
Monitor the actual position feedback value (e.g., via HMI or drive software) to observe the exact point at which the fault triggers.