SEW Eurodrive · MOVIDRIVE system
An error occurred while monitoring the signal level from Encoder 2, where the signal vector exceeded its permitted limit. This could indicate an issue with the encoder's physical mounting position affecting its signal output or data integrity.
Click steps to track your progress.
Inspect the mechanical mounting of Encoder 2 for loose bolts, shaft misalignment, or worn coupling elements.
Capture the differential Sin/Cos signals from Encoder 2 at drive terminal X2 using an oscilloscope to analyze signal amplitude and quality during rotation.
Verify that drive parameters P3-63 (Signal level minimum) and P3-64 (Signal level maximum) are set appropriately for the Encoder 2 type.
Check the encoder housing and shaft for any signs of physical damage or foreign material ingress that could affect internal sensing.
Temporarily disable high-frequency noise sources (e.g., switching power supplies, solenoids) in the vicinity to rule out external interference.