SEW Eurodrive · MOVIDRIVE system
A fault with a 'warning' response has occurred within the power section of the device. This indicates an underlying issue that could degrade drive performance, reduce reliability, and potentially escalate to a full operational fault if ignored.
Click steps to track your progress.
Monitor the drive's internal temperature sensors (e.g., Parameter P7-02, P7-03) and ensure ambient operating temperature is within specification.
Check the DC link voltage (e.g., Parameter P7-01) for stability and excessive ripple during operation with a multimeter in AC mode.
Reduce the motor load or adjust acceleration/deceleration ramps (e.g., Parameter P3-04, P3-05) to mitigate transient stress on the power section.
Visually inspect the power section for signs of discoloration, bulging components, or loose connections on the heatsink.
Verify the cooling fan is operating at its commanded speed (e.g., Parameter P7-01 or fan speed diagnostics) and not restricted by debris.