Siemens · SINAMICS S120/S150 Reference List
This alarm is initiated when the actual spindle temperature (r4105) exceeds the alarm threshold set in p4102[0] for the spindle's supplementary temperature evaluation. The alarm will clear once the temperature falls below this threshold value, factoring in a fixed 2 K hysteresis.
Click steps to track your progress.
1. Monitor the actual spindle temperature r4105 via the drive's diagnostics and compare it against the spindle motor's specifications.
2. Review the configured alarm threshold p4102[0] and adjust it if necessary, ensuring it allows for normal operational variance.
3. Inspect the spindle motor's cooling system for obstructions, proper fan operation, or adequate coolant levels and flow (for liquid-cooled systems).
4. Perform an acoustic and vibration analysis on the spindle to detect potential bearing wear or mechanical imbalance.
5. Reduce the spindle's load or speed settings (e.g., adjust machining parameters) temporarily to observe if the temperature drops below the alarm threshold.