Siemens · SINAMICS S120/S150 Reference List
A general fault has been detected at the drive object connected to the DRIVE-CLiQ socket X100. The fault value (r0949) provides information about the specific underlying fault that first occurred for this drive object. This fault requires immediate acknowledgment.
Click steps to track your progress.
1. Examine the DRIVE-CLiQ fault value r0949 to identify the specific error code reported by the device connected to X100.
2. Inspect the DRIVE-CLiQ cable connected to socket X100 for any physical damage, kinks, or stress points.
3. Verify that the DRIVE-CLiQ component connected to X100 is properly powered and its status LEDs indicate normal operation.
4. Reseat the DRIVE-CLiQ cable connector at both socket X100 and the connected component to ensure secure contact.
5. Swap the DRIVE-CLiQ cable connected to X100 with a known good cable of the same type and length.
6. Perform a DRIVE-CLiQ topology scan (e.g., using STARTER/SCOUT) to confirm all connected components are detected and configured correctly.