SV0383
PULSE MISS(EXT)
Fanuc · Alpha i Series Servo Amplifier
What does SV0383 mean?
A pulse error occurred on the separate detector, indicating that expected pulses were not detected. This impacts the accuracy of position feedback from the external detector.
Common Causes
- Electrical noise or interference on the external detector's pulse signal lines.
- Damage or slippage on the external detector's encoder disk.
- Faulty pulse generation circuitry within the external detector.
- External noise affecting the integrity of the pulse signal.
- Incorrect pulse output configuration in servo parameters.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Measure signal amplitude on external detector output terminals.
- 2
Inspect external detector encoder disk for scratches or misalignment.
- 3
Test external detector signal generation with diagnostic tools.
- 4
Install noise filters on power supply lines to the external detector.
- 5
Verify parameter P1-01 (Encoder Pulse Output) setting.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc Alpha i Series Servo Amplifier