What does SV0484 mean?
An error occurred in the servo's safety functions. This can be due to inexecution of servo software safety functions, a mismatch between servo software and CNC results for safety functions, or an error in a servo CPU or RAM test, indicating a critical safety system failure.
Common Causes
- Safety function logic has detected a conflict or malfunction.
- Safety PLC input signal mismatch or failure.
- Incorrect configuration of safety I/O modules.
- Overlapping or incompatible safety zones detected.
Repair Steps & Checklist
Click steps to track your progress.
- 1
If the cause is related to inexecution of servo software safety functions (condition 1), a servo CPU test error (condition 3), or a servo RAM test error (condition 4), replace the axis control card.