407

AC module temperature sensor faulty (L2)

Fronius · Primo GEN24 Operating Instructions

What does 407 mean?

This code indicates a fault with the temperature sensor monitoring the AC module for phase L2. A faulty sensor can lead to inaccurate temperature readings, potentially causing the inverter to operate outside safe thermal limits or prevent feed-in.

Common Causes

  • Malfunction of the temperature sensor itself for L2.
  • Break in the sensor's wiring or connection to the control board.
  • Damage to the sensor due to heat or mechanical stress.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for sensor inspection or replacement.

  2. 2

    Perform an AC reset to clear any transient sensor errors.

  3. 3

    Verify connections to the L2 AC module temperature sensor.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026