80
Platform Load is over 80%
Kone · Elevator Control
What does 80 mean?
The detected load on the platform exceeds 80% of its rated capacity. This is a warning only, indicating proximity to the maximum load limit.
Common Causes
- Platform loaded close to its maximum capacity.
- Malfunction of the platform overload sensor, providing an inaccurate reading.
- Uneven load distribution triggering the sensor prematurely.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the actual load on the elevator platform does not exceed 80% of rated capacity by observation.
- 2
Inspect load sensor wiring and connections for looseness, damage, or corrosion.
- 3
Check the load weighing device (sensor) for physical obstruction, debris, or misalignment.
- 4
Verify the configured rated capacity and load warning threshold parameters in the Kone elevator control system.
- 5
Perform a load weighing system re-calibration procedure as per manufacturer guidelines, if applicable.
Verified technical data. Last updated: March 2026