82

Output open error

SEW Eurodrive · Drives

What does 82 mean?

Two or all output phases between the MOVIMOT® inverter and the motor are interrupted. This can also occur if the rated motor power is too small compared to the nominal inverter power, affecting current distribution.

Common Causes

  • Interruption in two or all output phases connecting the inverter to the motor.
  • Faulty or disconnected wiring between the MOVIMOT® inverter and the motor.
  • Rated motor power is too small in relation to the nominal inverter power.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the electrical connection between the MOVIMOT® inverter and the motor for interrupted phases or loose connections.

  2. 2

    Verify that the combination of motor rated power and nominal inverter power is appropriate for the application.

Browse all codes in this manual (39)
Verified technical data. Last updated: March 2026