406

AC module temperature sensor faulty (L1)

Fronius · Primo GEN24 Operating Instructions

What does 406 mean?

This code indicates a fault with the temperature sensor monitoring the AC module for phase L1. A faulty sensor can lead to inaccurate temperature readings, potentially causing the inverter to operate outside safe thermal limits or prevent feed-in.

Common Causes

  • Malfunction of the temperature sensor itself for L1.
  • Break in the sensor's wiring or connection to the control board.
  • Damage to the sensor due to heat or mechanical stress.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for sensor inspection or replacement.

  2. 2

    Perform an AC reset to clear any transient sensor errors.

  3. 3

    Verify connections to the L1 AC module temperature sensor.